Electronics
Power cable (6kV~30kV) detectionList and introduce project standards
Power cable (6kV~30kV) detectionList and introduce project standards
Click here for online message:
Drop us a line
Service@Baijiantest.Com
Power cable (6kV~30kV) detectionList and introduce project standards

List of relevant testing items of 100 inspectionsThird-party testing institutions support sample sending and door-to-door testing, mainly providing sample testing services for companies, enterprises, public institutions, individual businesses, and university scientific research, and reporting CMA/CNAS/CAL qualifications, which are true and effective.

Testing process

1, sending samples

2, checking requirements

3, targeted quotation

4, both parties determine, sign a contract, start

the experiment

5, complete the experiment: the testing cycle (can be expedited) will be changed according to the sample and its testing items / methods, you can consult the engineer

6, issue a test report, and provide post-service.

This part of GB/T 12706 specifies the structure, dimensions, and test requirements for extruded insulated power cables with rated voltages ranging from 6 kV to 30 kV. This section is applicable to fixed installation of extruded insulated power cables with rated voltages ranging from 6kV to 30kV in distribution networks or industrial installations. This section is also applicable to longitudinal water resistant structural cables and their testing. When deciding on cable applications, it is advisable to consider the potential risk of radial water ingress. This section does not apply to cables with special installation and operating conditions, such as overhead cables, mining industries, nuclear power plants (inside and near the containment), as well as cables for underwater or ships. The following normative references are essential for the application of this document. For dated references, only the dated version applies to this document. For undated references, the latest version (including all modification orders) applies to this document. GB/T 156 Standard Voltage (GB/T 156-2017. IEC 60038:2009. MOD) GB/T 2951.11-2008 General Test Methods for Insulation and Sheath Materials of Electric and Optical Cables: Part 11: General Test Methods - Measurement of Thickness and Boundary Dimensions - Mechanical Performance Tests (IEC 60811-1:2001.1DT) GB/T 2951.12-2008 General Test Methods for Insulation and Sheath Materials of Electric and Optical Cables: Part 12: General Test Methods - Thermal Aging Test Method (IEC 60811-1-2:1985 · 1DT) GB/T 2951.13-2008 General Test Methods for Insulation and Sheath Materials of Electric and Optical Cables: Part 13: General Test Methods for Density Determination - Water Absorption Test and Shrinkage Test (IEC 60811-1-3:2001. IDT) GB/T 2951.14-2008 General Test Methods for Insulation and Sheath Materials of Electric and Optical Cables: Part 14: General Test Methods - Low Temperature Test (IEC 60811-1-4:1985,1DT) GB/T 2951.21-2008 General Test Methods for Insulation and Sheath Materials of Electric and Optical Cables: Part 21: Special Test Methods for Elastomer Mixtures, Ozone Resistance Test, Hot Elongation Test, Mineral Oil Immersion Test (IEC 60811-2-1:2001, IDT)

Function of testing report:

1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report

2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms

3. Used as a sales report: issuing legally effective testing reports to make consumers more confident

4. Papers and research: Provide professional personalized testing needs

5. Judicial services: providing scientific, fair, and accurate testing data

6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems

100% inspection and testing process:

1. Telephone communication and confirmation of requirements

2. Recommend solutions and confirm quotations

3. Mail samples and arrange testing

4. Progress tracking and result feedback

5. Provide reports and after-sales service

6. If urgent or priority processing is required

Testing and testing characteristics:

1. The testing industry is fully covered, meeting different testing needs

2. Fully cover the laboratory and allocate localized testing nearby

3. Engineers provide one-on-one services to make testing more accurate

4. Free initial testing, with no testing fees charged

5. Self service order delivery for free on-site sampling

6. Short cycle, low cost, and attentive service

7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc

8. The testing report is authoritative and effective, and is generally used in China

100 inspection and testing process:

1. Telephone communication and confirmation of needs;

2. Recommend the plan and confirm the quotation;

3. Mailing samples and arranging testing;

4. Progress tracking and result feedback;

5. Issue reports and after-sales service;

6. If it needs to be expedited, priority processing;