
Article 1.0.1 of Chapter 1 General Provisions aims to ensure the safe, normal operation, and economic rationality of the construction of television relay stations, broadcasting stations, overhead power lines, and substations; This standard is specially formulated. Article 1.0.2 This standard applies to the selection of new television relay stations and relay stations within the VHF (I) and VHF (I) frequency bands for receiving signals within the planning of broadcasting and television networks. It is also suitable for the construction, renovation, and expansion of AC overhead power lines and substations. Article 1.0.3: When overhead power lines and substations meet with independent FM broadcasting relay stations, they shall be protected according to the protective distance between VHF (I) segment TV relay stations and relay stations. Article 2.0.1 of Chapter 2 Protection Spacing: The protection spacing between overhead power lines of different voltage levels and TV differential and relay stations of each frequency band should not be less than the provisions in Table 2.0.1. Article 2.0.2: The protective distance between substations of different voltage levels and television differential stations and relay stations of each frequency band shall not be less than the provisions of Table 2.0.2. Article 2.0.3: When the protective distance specified in Table 2.0.1 cannot be met, the protective distance can be determined by measuring and calculating according to Appendix - "Calculation Method for Protective Distance"; When the requirements cannot be met, the following measures can be taken to reduce the intensity of the interference electric field and determine the protective distance. 1、 Strengthen the cleaning of polluted insulators in overhead power lines to ensure good contact between fittings. 2、 When an overhead power line passes near a television relay or broadcasting station, it should try to pass through the non main receiving direction of the television relay or broadcasting station as much as possible. 3、 Measures to reduce the surface electric field strength of conductors can be adopted for overhead power lines in local areas, and measures to reduce the surface electric field strength of busbars and equipment leads can be adopted in substations. 4、 In areas with severe salt fog along the coast, the protective distance should not be reduced. 5、 Improve the receiving antennas of television relay stations and relay stations, such as using a multi unit directional antenna array. The commonly used multi element directional antenna array is a five element directional antenna array. According to different situations, a binary horizontal array (dual column), a binary vertical array (dual layer), and a dual layer dual column quaternion array can be formed. 6、 If necessary, change the transmission method of television signals, such as using microwave transmission, satellite transmission, etc P>
Function of testing report:
1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report
2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms 3. Used as a sales report: issuing legally effective testing reports to make consumers more confident 4. Papers and research: Provide professional personalized testing needs 5. Judicial services: providing scientific, fair, and accurate testing data 6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problemsBaijian and testing process:
1. Telephone communication and confirmation of requirements
2. Recommend solutions and confirm quotations 3. Mail samples and arrange testing 4. Progress tracking and result feedback 5. Provide reports and after-sales service 6. If urgent or priority processing is requiredTesting and testing characteristics:
1. The testing industry is fully covered, meeting different testing needs
2. Fully cover the laboratory and allocate localized testing nearby3. Engineers provide one-on-one services to make testing more accurate
4. Free initial testing, with no testing fees charged
5. Self service order delivery for free on-site sampling
6. Short cycle, low cost, and attentive service 7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc 8. The testing report is authoritative and effective, and is generally used in China