Detection of contact current and protective conductor current
Detection of contact current and protective conductor current
Click here for online message:
Drop us a line
Service@Baijiantest.Com
Detection of contact current and protective conductor current

Electronic switching technology is widely used in power systems and equipment, resulting in high-frequency harmonic voltage and high-frequency harmonic current. The formulation of this standard aims to solve the related problems arising from this. This standard is intended to provide guidance for the Equipment Committee in developing or revising test specifications for measuring leakage current in its standards. However, the term 'leakage current' is no longer used for the reasons described below. This standard is formulated based on the safety leadership responsibilities assigned to the Equipment Committee, in the following aspects. The method of measuring leakage current includes various aspects of different types of equipment called "leakage current", including the measurement methods related to physiological effects and installation situations under normal and certain fault conditions. The measurement method for leakage current described here was developed through research on IEC 60479-1 and other publications, including descriptions of early measurement methods. The following conclusions have been drawn from the study of leakage current effects: - - In terms of safety, the main consideration is the harmful current that may flow through the human body (this current may not necessarily be equal to the current flowing through the protective conductor)—— It has been found that the effect of electric current on the human body is more complex than the several human effects that were considered in the early formulation of standards. The most important human effects based on which limits are specified for continuous waveforms are: perception; reaction avoidance; and electric burns. Each of these four human effects has a separate threshold, and some of these thresholds vary greatly with frequency. It has been determined that there are two types of currents that require separate measurement methods: contact current and protective conductor current. Contact current only exists when the human body or human model forms a current path. It should also be noted that the term 'leakage current' has been used to express several different concepts, such as contact current, protective conductor current, insulation characteristics, etc. Therefore, the term 'leakage current' is not used in this standard

Function of testing report:

1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report

2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms

3. Used as a sales report: issuing legally effective testing reports to make consumers more confident

4. Papers and research: Provide professional personalized testing needs

5. Judicial services: providing scientific, fair, and accurate testing data

6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems

Baijian and testing process:

1. Telephone communication and confirmation of requirements

2. Recommend solutions and confirm quotations

3. Mail samples and arrange testing

4. Progress tracking and result feedback

5. Provide reports and after-sales service

6. If urgent or priority processing is required

Testing and testing characteristics:

1. The testing industry is fully covered, meeting different testing needs

2. Fully cover the laboratory and allocate localized testing nearby

3. Engineers provide one-on-one services to make testing more accurate

4. Free initial testing, with no testing fees charged

5. Self service order delivery for free on-site sampling

6. Short cycle, low cost, and attentive service

7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc

8. The testing report is authoritative and effective, and is generally used in China