
This part of GB 1094 is applicable to equipment with a maximum voltage of 40.5kV and below, And at least one winding is more reliable when the voltage is higher than 1.1kV - Multiphase transformers with rated capacity less than 15kVA; - Transformer; - Starting transformer; - Test transformer; - Locomotive traction transformer; - Flameproof and mining transformer; - Welding transformer; - Voltage regulating transformer; - Small power transformer with a focus on safety considerations. When there are no corresponding standards for the above transformers or other specialized transformers, this part can be fully or partially applied. 2 Normative reference documents The clauses in the following documents are referred to in GB The reference in this part of 1094 becomes the provision of this part. For dated reference documents, all subsequent amendments (excluding corrected content) or revisions do not apply to this section. However, parties to agreements based on this section are encouraged to study whether the latest versions of these documents can be used. For undated references, the latest version applies to this section. GB 311.1 Insulation Coordination of High Voltage Transmission and Transformation Equipment (GB 311.1-1997, neq IEC 60071-1:1993) GB 1094.1 Power Transformers: Part 1: General (GB 1094.1-1996, eqv 1EC 60076-1:1993) GB 1094.2 Power Transformers: Part 2: Temperature Rise (GB 1094.2-1996.eqv 1EC 60076-2; 1993) GB 1094.3 Power Transformers: Part 3: Insulation Levels, Insulation tests and external insulation air gaps (GB 1094.3-2003, IEC 60076-3; 2000, MOD) GB 1094.5 Power transformers: Part 5: Ability to withstand short circuits (GB 1094.5-2003, IEC 60076-5; 2000. MOD) GB/T 1094.10 Power transformers: Part 10: Sound level measurement (GB/T 1094.10-2003, IEC 60076-10; 2001. MOD) GB/T 2900.15 Electrotechnical terminology, transformers, transformers Voltage Regulators and Reactors (GB/T 2900.15-1997, neqIEC 60050-421:1990, EC 60050-321:1986) GB 4208 Degrees of Protection Provided by Enclosures (IP Code) (GB 4208-1993. eqv IEC 60529; 1989) GB/T 7354 Partial Discharge Measurement (GB/T 7354-2003, EC 60270:2000, IDT) GB/T 11021 Thermal Evaluation and Classification of Electrical Insulation (GB/T 11021-1989, eqv 1EC 60085; 1984) GB/T 17211-1998 Load Guidelines for Dry Power Transformers (eqv lEC 60905:1987)
Function of testing report:
1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report
2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms 3. Used as a sales report: issuing legally effective testing reports to make consumers more confident 4. Papers and research: Provide professional personalized testing needs 5. Judicial services: providing scientific, fair, and accurate testing data 6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problemsBaijian and testing process:
1. Telephone communication and confirmation of requirements
2. Recommend solutions and confirm quotations 3. Mail samples and arrange testing 4. Progress tracking and result feedback 5. Provide reports and after-sales service 6. If urgent or priority processing is requiredTesting and testing characteristics:
1. The testing industry is fully covered, meeting different testing needs
2. Fully cover the laboratory and allocate localized testing nearby3. Engineers provide one-on-one services to make testing more accurate
4. Free initial testing, with no testing fees charged
5. Self service order delivery for free on-site sampling
6. Short cycle, low cost, and attentive service 7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc 8. The testing report is authoritative and effective, and is generally used in China