Intermittent disturbance analysis and measurement equipment should comply with the provisions of Chapter 10 of CISPR 16-1-1:2003. As long as the accuracy is sufficient, an alternative method of oscilloscope can be used. Note: For the measurement of disturbance duration, refer to CISPR 16-1-1:2003. 5.2 Measurement procedures and arrangement of test tool leads. More information on the connection between electrical appliances and measuring equipment is provided in Chapter 5 and Appendix A of CISPR 16-2-1:2003. 5.2.1.1 In all terminal voltage (power terminal or other terminals) disturbance measurements, the V-type artificial power network should be connected to the power terminal to provide a specified terminal. As mentioned in 5.2.2, the position of the V-shaped network should be 0.8 meters away from the appliance, and the disturbance voltage is usually measured at the plug end of the lead. If the power lead of the test instrument exceeds the length required to connect to the V-shaped artificial power network, the part exceeding 0.8 m should be folded back and forth parallel to the power lead to form a horizontal harness between 0.3 m and 0.4 m in length. If there is a dispute regarding the prohibition of sales or the cancellation of type approval, a 1m long fake quality lead can be used to replace the power lead. If the lead to be measured is shorter than the required distance between the appliance and the V-shaped artificial power network, the lead should be extended to the necessary length. If there is a grounding wire in the power lead of the tested instrument, the plug end of the grounding wire should be connected to the reference ground of the measuring device. When a grounding wire is required and is not included in the power lead, the grounding terminal of the test instrument should be connected to the reference ground of the measuring device using a lead wire. The length of the lead wire should not exceed the length required to connect to the V-shaped artificial power network, and the lead wire should be parallel to the power lead wire and not more than 0.1 meters apart p> If the appliance does not provide a power lead, a lead not exceeding 1 meter (including a plug or socket) should be used to connect the appliance to the V-shaped artificial power network P>
Function of testing report:
1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report
2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms 3. Used as a sales report: issuing legally effective testing reports to make consumers more confident 4. Papers and research: Provide professional personalized testing needs 5. Judicial services: providing scientific, fair, and accurate testing data 6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problemsBaijian and testing process:
1. Telephone communication and confirmation of requirements
2. Recommend solutions and confirm quotations 3. Mail samples and arrange testing 4. Progress tracking and result feedback 5. Provide reports and after-sales service 6. If urgent or priority processing is requiredTesting and testing characteristics:
1. The testing industry is fully covered, meeting different testing needs
2. Fully cover the laboratory and allocate localized testing nearby3. Engineers provide one-on-one services to make testing more accurate
4. Free initial testing, with no testing fees charged
5. Self service order delivery for free on-site sampling
6. Short cycle, low cost, and attentive service 7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc 8. The testing report is authoritative and effective, and is generally used in China