
Scope of application: This part of GB 13140 is applicable to connecting devices used as independent units for household and similar purposes. The AC rated voltage of these connecting devices should not exceed 1000 V and the frequency should not exceed 1000 Hz; The rated DC voltage should not exceed 1500 V; Electrically, it should be possible to connect two or more hard copper wires (solid or stranded) or soft copper wires with a cross-sectional area of 0.2 mm~35 mm '(including 35 mm') or corresponding AWG wire specifications. These hard or soft copper wires should comply with the requirements of GB/T 3956-2008 or GB/T 18213-2000. Note. For wires with a rated connection capacity less than 0.5 mm, refer to GB/T 18213-2000, and for wires with a rated connection capacity greater than or equal to 0.5 mm, refer to GB/T 3956-2008. Except for twisted connection devices and insulated connectors with piercing, connectors that meet the requirements of this section should not require the use of special tools for connection. This section is a general requirement, It should be used in conjunction with Part 2 Special Requirements (hereinafter referred to as "Part 2"): - Devices with threaded clamping pieces (GB 13140.2) - Devices with unthreaded clamping pieces (GB 13140.3> - Connecting devices with piercing insulation clamping pieces (GB 13140.4) - Devices with twisted connections (GB 13140.5) Test standards: GB/T 2423.8-1995 Environmental testing for electrical and electronic products, Part 2: Test methods, Test Ea: Free fall (IEC 60068-2-32:1990,1DT) GB/T 2423.55-2006 Environmental Testing for Electrical and Electronic Products - Part 2: Test Methods - Test Eh: Hammer Impact Test (IEC 60068-2-75:1997. IDT) GB/T 3956-2008 Conductors of Cables (IEC 60228:2004, IDT) GB/T 4207-2003 Solid Insulation Materials - Determination of Relative and Resistance to Traceability Index under Wet Conditions (idt IEC 60112:1979) GB 4208 Degrees of Protection Provided by Enclosures (IP Code) (GB 4208-2008 IEC 60529; 2001, IDT) GB/T 5169.10-2006 Fire Hazard Testing for Electrical and Electronic Products, Part 10; Glow Wire/Glow Wire Basic Test Methods - Glow Apparatus and General Test Methods (IEC 60695-2-10:2000, 1DT) GB/T9797-2005 Metallic Coatings, Nickel+Chromium and Copper+Nickel+Chromium Electroplated Coatings (ISO 1456; 2003, 1DT) GB/T9799-1997 Metallic Coatings - Zinc Electroplated Coatings on Steel (eqv 1SO 20811986) GB/T 12599-2002 Metallic Coatings - Tin Electroplated Coatings: Technical Specifications and Test Methods (ISO 2093:1986, MOD) GB/T16842-2008 Protection of Persons and Equipment by Enclosures, Test Tools for Inspection (IEC 61032:1997,1DT) GB/T 18213-2000 Guide for Calculation of Resistance of Uncoated and Coated Copper Conductors for Low Frequency Cables and Wires (idt IEC 60344:1980)
Function of testing report:
1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report
2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms 3. Used as a sales report: issuing legally effective testing reports to make consumers more confident 4. Papers and research: Provide professional personalized testing needs 5. Judicial services: providing scientific, fair, and accurate testing data 6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problemsBaijian and testing process:
1. Telephone communication and confirmation of requirements
2. Recommend solutions and confirm quotations 3. Mail samples and arrange testing 4. Progress tracking and result feedback 5. Provide reports and after-sales service 6. If urgent or priority processing is requiredTesting and testing characteristics:
1. The testing industry is fully covered, meeting different testing needs
2. Fully cover the laboratory and allocate localized testing nearby3. Engineers provide one-on-one services to make testing more accurate
4. Free initial testing, with no testing fees charged
5. Self service order delivery for free on-site sampling
6. Short cycle, low cost, and attentive service 7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc 8. The testing report is authoritative and effective, and is generally used in China