Electronics
Fixed resistance network detection
Fixed resistance network detection
Click here for online message:
Drop us a line
Service@Baijiantest.Com
Fixed resistance network detection

This specification specifies the general requirements for film fixed resistor networks, film fixed resistors, and ceramic capacitor resistance capacitance networks. This specification applies to the fixed resistance networks of airtight and non airtight sealing membranes, as well as the resistance and capacitance networks of membrane fixed resistors and ceramic capacitors. These networks are composed of membrane fixed resistors or membrane fixed resistors and ceramic capacitors. This specification specifies two levels of products, one being highly reliable The "M" grade product selected for 100% power aging, and the other type is the "C" grade product selected for non power aging. The relevant clauses in the following documents become the clauses of this specification through reference. For dated or revised reference documents, any subsequent modification orders (excluding corrected content) Neither the revised version is applicable to this specification, but it is suggested that all parties using this specification explore the possibility of using its latest version. For referenced documents without date or revision, the latest version applies to this specification. GBT 191 Packaging, Storage and Transportation Graphical Symbols GB/T2471 Priority Number System for Resistors and Capacitors GB/T 2691 Marking Code for Resistors and Capacitors GJB 150.10-1986 Environmental Testing Methods for Military Equipment GJB 360A-1996 Test Methods for Electronic and Electrical Components GJB 546 Quality Assurance Outline for Electronic Components GJB 1437-1992 Quality Assurance Requirements for Electronic Component Leads GJB 2712 Measurement Equipment Metrological Confirmation System 3 Requirements 3.1 General Network Requirements should comply with All requirements of this specification and corresponding detailed specifications. In case of any inconsistency between the requirements of this specification and the relevant detailed specifications, the relevant detailed specifications shall prevail. The manufacturer shall establish and maintain the requirements of the quality assurance program in accordance with the provisions of GB 546. The network supplied according to this specification should be a product that has been identified as qualified. 3.2 Materials should be selected that enable the network to meet the performance requirements of this specification. The acceptance or recognition of any constituent materials shall not be used as a basis for the acceptance of finished products. To maximize the use of recyclable materials or environmentally friendly materials. 3.3 Design, structure, and overall dimensions 3.3.1 The general network should have the design, structure, and overall dimensions specified in the relevant detailed specifications. According to the relevant detailed specifications, each network should be composed of membrane resistor elements with outgoing terminals, or membrane resistor elements with outgoing terminals and ceramic capacitors. 3.3.2 The packaging of Alo should be intact to withstand the specified environmental tests. For internal circuits, the packaging should have no pores. 3.3.3 Lead out end - It should be free of foreign impurities and have the specified weldability. If it meets the appearance criteria, it should be considered that the leading-out end does not contain foreign impurities

Function of testing report:

1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report

2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms

3. Used as a sales report: issuing legally effective testing reports to make consumers more confident

4. Papers and research: Provide professional personalized testing needs

5. Judicial services: providing scientific, fair, and accurate testing data

6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems

Baijian and testing process:

1. Telephone communication and confirmation of requirements

2. Recommend solutions and confirm quotations

3. Mail samples and arrange testing

4. Progress tracking and result feedback

5. Provide reports and after-sales service

6. If urgent or priority processing is required

Testing and testing characteristics:

1. The testing industry is fully covered, meeting different testing needs

2. Fully cover the laboratory and allocate localized testing nearby

3. Engineers provide one-on-one services to make testing more accurate

4. Free initial testing, with no testing fees charged

5. Self service order delivery for free on-site sampling

6. Short cycle, low cost, and attentive service

7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc

8. The testing report is authoritative and effective, and is generally used in China