Electronics
Fixed acid proof lead-acid battery testing
Fixed acid proof lead-acid battery testing
Click here for online message:
Drop us a line
Service@Baijiantest.Com
Fixed acid proof lead-acid battery testing

This part of GB/T 13337 specifies the technical conditions for fixed exhaust lead-acid batteries (hereinafter referred to as batteries), including technical requirements, test methods, inspection rules, marking, packaging, transportation, and storage tests. This section is applicable to switches, safety protection devices, signal systems, telecommunications devices, computers, emergency lighting, and various DC power supply batteries and battery packs. This section does not apply to fixed valve regulated lead-acid batteries and lead-acid batteries for energy storage. The following normative references are essential for the application of this document. For dated references, only the dated version applies to this section. For undated references, the latest version (including all modification orders) applies to this document. GB/T 2900.41 Electrotechnical Terminology - Primary Batteries and Accumulators - GB/T 13337.2 Fixed Exhaust Lead Acid Batteries - Part 2: Specifications and Dimensions - IEC 60896-11:2002 Fixed Exhaust Lead Acid Batteries - Part 11: General Requirements and Test Methods - Terms, Definitions and Symbols - The terms and definitions defined in GB/T 2900.41 apply to this document. The following symbols apply to this document. C—— The actual capacity of the battery at the reference temperature (25 ℃), in ampere hours (A · h); C. - The measured capacity of the battery is the product of discharge current I and discharge time t, in ampere hours (A · h); Ca, s - rated capacity at a rate of 0.5 hours, with a value of 0.35Co, in ampere hours (A · h); C -1-hour rated capacity, with a value of 0.45Co, in ampere hours (A · h); Ci. -- 10 hour rated capacity, in ampere hours (A - h); 1o.s -0.5 hour rate discharge current, with a value of 7I., Unit: Ampere (A); I -1-hour rate discharge current, with a value of 4.5Io, in amperes (A); Ix. -- 10 hour rate discharge current, value C/ 10, in amperes (A); R - Charge retention capacity; U—— The charging voltage of a single battery during constant voltage charging, ranging from 2.25 to 2.40, in volts (V); U - The charging voltage of a single battery during trickle charging, ranging from 2.15 to 2.25, in volts (V)

Function of testing report:

1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report

2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms

3. Used as a sales report: issuing legally effective testing reports to make consumers more confident

4. Papers and research: Provide professional personalized testing needs

5. Judicial services: providing scientific, fair, and accurate testing data

6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems

Baijian and testing process:

1. Telephone communication and confirmation of requirements

2. Recommend solutions and confirm quotations

3. Mail samples and arrange testing

4. Progress tracking and result feedback

5. Provide reports and after-sales service

6. If urgent or priority processing is required

Testing and testing characteristics:

1. The testing industry is fully covered, meeting different testing needs

2. Fully cover the laboratory and allocate localized testing nearby

3. Engineers provide one-on-one services to make testing more accurate

4. Free initial testing, with no testing fees charged

5. Self service order delivery for free on-site sampling

6. Short cycle, low cost, and attentive service

7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc

8. The testing report is authoritative and effective, and is generally used in China