
Scope 1.1 This section specifies the technical requirements, test items, markings, packaging, etc. for the excitation system of synchronous generators and condensers. This standard applies to the excitation system of 10 MW and above hydro generators connected to the power system, 50 MW and above turbine synchronous generators and condensers. The excitation system of the generator motor can be used as a reference. 1.2 This section only applies to the following types of excitation systems. 1.2.1 AC exciter excitation system a) AC exciter with static rectifier; b) AC exciter with rotating rectifier (brushless excitation system). 1.2.2 Static excitation system a) Potential source static excitation system; b) Composite source static excitation system. 2 Normative References: The clauses contained in the following documents become the clauses of this section through reference in this section. For dated reference documents, all subsequent amendments (excluding corrected content) or revisions do not apply to this section. However, parties to agreements based on this section are encouraged to study whether the latest versions of these documents can be used. For undated references, the latest version applies to this section. GB 755: Rating and Performance of Rotating Electrical Machines (GB 755-2000, idt IEC 60034-1:1996) GB 1094 (All Parts) Power Transformers (GB 1094.1-1996.eqv IEC 60076-11993; GB 1094.2-1996, eqv IEC 60072-2:1993; GB 1094.3-2003, IEC 60076-3; 2000, MOD; GB 1094.5-2003, IEC 60076-5:2o0o, MOD) GB 3797 Electrical Control Equipment Part 2: Electrical Control Equipment Equipped with Electronic Devices GB 6450 Dry Power Transformers (GB 6450-1986, eqv IEC 60726; 1982) GB/T 7064 Technical Conditions for Turbine Synchronous Motors (GB/T 7064-2002, IEC 60034-31988, NEQ GB/T 7409.1 Excitation Systems for Synchronous Motors, Definitions (GB/T 7409.1-1997, idt IEC 60034-16:1991) GB/T 7409.2 Excitation Systems for Synchronous Motors, Models for Power System Stability Research (GB/T 7409.2-1997, idt 1EC 60034-16-2:1991) GB/T 7894 Basic Technical Conditions for Hydrogenerators (GB/T 7894-2001, neq IEC 60034-1:1996) GB/T 14598 Electrical Interference Testing for Measuring Relays and Protection Devices (GB/T 14598.1-2002, IEC 60255-23:1994. IDT; GB/T 14598.2-1993. eqv IEC 60255-1-00; 1975; GB/T 14598.3-1993. eqv IEC 60255-5:1997; GB/T 14598.4-1993, idt IEC 60255-14:1981; GB/T 14598.5-1993 idt IEC 60255-15:1981; GB/T 14598.6-1993, idt IEC 60255-18:1982; GB/T 14598.7-1995, idt IEC 60255-3: 1989GB/T 14598.8-1995, idt IEC 60255-202: 1984; GB/T 14598.9-2002, idt IEC 60255-22-3:2000, IDT; GB/T 1459 8.10-1996, idt EC 60255-22-4:1992; GB/T 14598.11-1997, idt IEC 60255-19:1983; GB/T 14598.12-1998, idt IEC 60255-19:1983; GB/T 14598.13-1998, eqv IEC 60255-22-1:1988; GB/T 14598.14-1998, idt IEC 60255-22-2:1996; GB/T 14598.15-1998, idt IEC 60255-8 1990; GB/T 14598.16-2002.1EC60255-25; 2000,1DT)
Function of testing report:
1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report
2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms 3. Used as a sales report: issuing legally effective testing reports to make consumers more confident 4. Papers and research: Provide professional personalized testing needs 5. Judicial services: providing scientific, fair, and accurate testing data 6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problemsBaijian and testing process:
1. Telephone communication and confirmation of requirements
2. Recommend solutions and confirm quotations 3. Mail samples and arrange testing 4. Progress tracking and result feedback 5. Provide reports and after-sales service 6. If urgent or priority processing is requiredTesting and testing characteristics:
1. The testing industry is fully covered, meeting different testing needs
2. Fully cover the laboratory and allocate localized testing nearby3. Engineers provide one-on-one services to make testing more accurate
4. Free initial testing, with no testing fees charged
5. Self service order delivery for free on-site sampling
6. Short cycle, low cost, and attentive service 7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc 8. The testing report is authoritative and effective, and is generally used in China