
A) Connect two probes (regardless of positive or negative) to the pins at both ends of the resistor to measure the actual resistance value. In order to improve measurement accuracy, the range should be selected based on the nominal value of the measured resistance. Due to the nonlinear relationship of the ohmic scale, the middle section of the scale is relatively fine. Therefore, the pointer should be positioned as close as possible to the middle section of the scale, which is within the range of 20% -80% radians from the beginning of the full scale, in order to make the measurement more accurate. Depending on the level of resistance error. An error of ± 5%, ± 10%, or ± 20% is allowed between the reading and the nominal resistance value, respectively. If it does not match and exceeds the error range, it indicates that the resistance value has changed. B) Be careful not to touch the conductive parts of the probe and resistance during testing, especially when measuring resistance values of tens of k Ω or above; The tested resistance should be soldered off from the circuit, at least one head should be soldered open to prevent other components in the circuit from affecting the test and causing measurement errors; Although the resistance value of the color ring resistor can be determined by the color ring symbol, it is best to use a multimeter to test its actual resistance value when using it. 2. The method and precautions for detecting cement resistance are identical to those for detecting ordinary fixed resistors. 3. The detection of fused resistors in a circuit can be made based on experience when the fused resistor is blown open. If the surface of the fused resistor is found to be black or burnt, it can be concluded that its load is too heavy and the current passing through it exceeds the rated value many times; If there are no traces on its surface and there is an open circuit, it indicates that the current flowing is just equal to or slightly greater than its rated fuse value. For the judgment of the quality of a fused resistor without any trace on the surface, a multimeter R can be used × To ensure accurate measurement, one end of the fuse resistor should be soldered off the circuit in gear 1. If the measured resistance value is infinite, it indicates that the fused resistor has failed and is open circuit. If the measured resistance value differs significantly from the nominal value, it indicates that the resistance has changed and should not be used again. In maintenance practice, it has been found that there are also a few fuse resistors that are broken down and short circuited in the circuit, and attention should also be paid during testing P>
Function of testing report:
1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report
2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms 3. Used as a sales report: issuing legally effective testing reports to make consumers more confident 4. Papers and research: Provide professional personalized testing needs 5. Judicial services: providing scientific, fair, and accurate testing data 6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problemsBaijian and testing process:
1. Telephone communication and confirmation of requirements
2. Recommend solutions and confirm quotations 3. Mail samples and arrange testing 4. Progress tracking and result feedback 5. Provide reports and after-sales service 6. If urgent or priority processing is requiredTesting and testing characteristics:
1. The testing industry is fully covered, meeting different testing needs
2. Fully cover the laboratory and allocate localized testing nearby3. Engineers provide one-on-one services to make testing more accurate
4. Free initial testing, with no testing fees charged
5. Self service order delivery for free on-site sampling
6. Short cycle, low cost, and attentive service 7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc 8. The testing report is authoritative and effective, and is generally used in China