YY9706.102 specifies the general requirements and tests for electromagnetic compatibility of ME equipment and ME systems. These general requirements and tests are not only general standard requirements, but also serve as the basis for specialized standards The ME system or ME system can operate in its electromagnetic environment in accordance with requirements and does not constitute an unbearable electromagnetic interference capability (electromagnetic compatibility EMC) for anything in that environment The testing items required for electromagnetic compatibility of medical electrical equipment in YY9706.102-2021 include:

Electrostatic discharge test, electrical fast transient pulse group test, surge test, voltage sag short interruption and voltage change test on the power input line, power frequency magnetic field test, harmonic emission test, voltage fluctuation/flicker emission test, radio frequency conduction test, radio frequency radiation test, radiation emission test, and conducted emission test The electromagnetic compatibility immunity test level of medical electrical equipment is above or below level 3, and the test level is not too high. According to the type of product, select the attached testing requirements of the standard for testing

Reference to electromagnetic compatibility testing standards:

Electromagnetic compatibility requirements for household appliances, electric tools, and similar appliances - Part 1: Emission GB 4343.1-2018

Limits and measurement methods for radio frequency disturbance characteristics of industrial, scientific, and medical equipment GB 4824-2019, IEC CISPR 11:2016

Radio frequency disturbance limits and measurement methods for information technology equipment GB/T 9254-2008,

, CISPR 22:2006

Electromagnetic Compatibility Limits Harmonic Current Emission Limits (Equipment Input Current ≤ 16A per phase) GB 17625.1-2012, IEC 61000-3-2:2009 Ed.3.2

Electromagnetic Compatibility Limits: Limitations on Voltage Changes, Voltage Fluctuations, and Flashing in Public Low Voltage Power Supply Systems for Equipment with a Rated Current ≤ 16A per phase and Unconditional Access GB/T 17625.2-2007, IEC 61000-3-3:2005

Electromagnetic compatibility testing and measurement techniques - Electrostatic discharge immunity test GB/T17626.2-2018, IEC 61000-4-2:2008

Electromagnetic compatibility testing and measurement techniques - Radio frequency electromagnetic field radiation immunity test GB/T 17626.3-2016, IEC 61000-4-3:2010

Electromagnetic compatibility testing and measurement techniques - Electrical fast transient pulse group immunity test GB/T 17626.4-2018, IEC 61000-4-4:2012

Electromagnetic Compatibility Testing and Measurement Techniques Surge (Impact) Immunity Test GB/T 17626.5-2019, IEC 61000-4-5:2014

Electromagnetic Compatibility Testing and Measurement Techniques Conducted Disturbance Induced by Radio Frequency Fields GB/T 17626.6-2017, IEC 61000-4-6: 2013

Electromagnetic Compatibility Testing and Measurement Techniques Power Frequency Magnetic Field Immunity Test GB/T 17626.8-2006,

, IEC 61000-4-8:2001

Electromagnetic compatibility testing and measurement techniques - Immunity tests for voltage dips, short interruptions, and voltage changes at DC power input ports (GB/T 17626.29-2006, IEC 61000-4-29:2000)

Function of testing report:

1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report

2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms

3. Used as a sales report: issuing legally effective testing reports to make consumers more confident

4. Papers and research: Provide professional personalized testing needs

5. Judicial services: providing scientific, fair, and accurate testing data

6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems

Baijian and testing process:

1. Telephone communication and confirmation of requirements

2. Recommend solutions and confirm quotations

3. Mail samples and arrange testing

4. Progress tracking and result feedback

5. Provide reports and after-sales service

6. If urgent or priority processing is required

Testing and testing characteristics:

1. The testing industry is fully covered, meeting different testing needs

2. Fully cover the laboratory and allocate localized testing nearby

3. Engineers provide one-on-one services to make testing more accurate

4. Free initial testing, with no testing fees charged

5. Self service order delivery for free on-site sampling

6. Short cycle, low cost, and attentive service

7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc

8. The testing report is authoritative and effective, and is generally used in China