Electronics
Products with input current ≤ 16A per phase/electromagnetic compatibility testing
Products with input current ≤ 16A per phase/electromagnetic compatibility testing
Click here for online message:
Drop us a line
Service@Baijiantest.Com
Products with input current ≤ 16A per phase/electromagnetic compatibility testing

Electromagnetic compatibility (EMC) - Part 3-3: Limits - Voltage variations in public low-voltage power supply systems for equipment with a rated current of not more than 16A per phase and without the need for conditional connection Limits to voltage fluctuations and flicker IEC 61000-3-3:2017 Electrostatic discharge immunity Electromagnetic compatibility testing and measurement techniques Electrostatic discharge immunity testing GB/T 17626.2-2006 Electromagnetic compatibility (EMC) Part 4-2: Testing and measurement techniques Electrostatic discharge immunity testing IEC 61000-4-2:2008 Radio frequency electromagnetic field radiation immunity Electromagnetic compatibility testing and measurement techniques Radio frequency electromagnetic field radiation immunity testing GB/T 17626.3-2016 Electromagnetic compatibility (EMC) Part 4-3: Testing and measurement techniques - Radiation Immunity tests for radio frequency and electromagnetic fields IEC 61000-4-3:2010 Electrical fast transient pulse group immunity Electromagnetic compatibility testing and measurement techniques Electrical fast transient pulse group immunity test GB/T 17626.4-2008 Electromagnetic compatibility (EMC) Part 4-4: Testing and measurement techniques Electrical fast transient pulse group immunity test IEC 61000-4-4:2012 Surge (impact) immunity Electromagnetic compatibility testing and measurement techniques Surge (impact) Immunity Testing GB/T 17626.5-2008 Electromagnetic Compatibility (EMC) Part 4-5: Testing and Measurement Techniques Impact Immunity Testing IEC 61000-4-5:2014 Conducted Disturbances Induced by RF Fields Electromagnetic Compatibility Testing and Measurement Techniques Conducted Disturbances Induced by RF Fields Immunity GB/T 17626.6-2008 Electromagnetic Compatibility (EMC) Part 4-6: Testing and Measurement Techniques Conducted Disturbances Induced by RF Fields Immunity IEC 61000-4:6:2013 Voltage Dips Electromagnetic compatibility testing and measurement techniques - Immunity to short interruptions and voltage changes - Voltage dips, short interruptions and voltage changes - Immunity testing GB/T 17626.11-2008- Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips Immunity tests for short-term interruptions and voltage changes IEC61000-4-11:2004 Ringing wave immunity tests Electromagnetic compatibility tests and measurement techniques Ringing wave immunity tests GB/T 17626.12-2013 Electromagnetic compatibility (EMC) Part 4-12: Testing and measurement techniques Ringing wave immunity tests IEC61000-4-12:2017 Damping oscillation wave immunity tests Electromagnetic compatibility (EMC) Part 4-18: Testing and measurement techniques Damping oscillation wave immunity test IEC 61000-4-18:2011 Power frequency magnetic field immunity electromagnetic compatibility testing and measurement techniques Power frequency magnetic field immunity test GB/T 17626.8-2006 Electromagnetic compatibility (EMC). Part 4-8: Testing and measurement techniques Power frequency magnetic field immunity test IEC 61000-4-8:2009 DC power supply input port voltage sag Immunity to short-term interruptions and voltage changes Electromagnetic compatibility testing and measurement techniques Immunity tests for voltage dips, short-term interruptions and voltage changes at DC power input ports GB/T 17626.29-2006 Electromagnetic compatibility (EMC) Part 4-29: Testing and measurement techniques Immunity tests for voltage dips, short-term interruptions and voltage changes at DC input power terminals IEC 61000-4-29:2000 Harmonics at AC power supply ports Electromagnetic compatibility testing and measurement techniques for low-frequency immunity of harmonic waves and power grid signals - Harmonics at AC power supply ports Low frequency immunity test for harmonic waves and power grid signals GB/T 17626.13-2006 Electromagnetic compatibility (EMC) Part 4-13: Testing and measurement techniques. Low frequency immunity tests for harmonics and interharmonics of power supply signals, including AC ports. IEC 61000-4-13: 2009 Voltage fluctuation immunity. Electromagnetic compatibility tests and measurement techniques. Voltage fluctuation immunity tests. GB/T 17626.14-2005 Electromagnetic compatibility tests and measurement techniques. Part 4-14: Voltage fluctuation immunity tests. IEC 61000-4-14: 2009 Power frequency variation immunity. Electromagnetic compatibility tests and measurement techniques Frequency variation immunity test GB/T 17626.28-2006 Electromagnetic compatibility (EMC) Part 4-28: Testing and measurement techniques - Power supply frequency variation and immunity tests for equipment with input current ≤ 16A/phase IEC 61000-4-28: 2009 DC power supply input port ripple immunity Electromagnetic compatibility testing and measurement techniques DC power supply input port ripple immunity test GB/T 17626.17-2005 Electromagnetic compatibility testing and measurement techniques Part 4-17: DC power supply input port ripple immunity test IEC 61000-4-17:2009 Main power supply per phase Immunity to voltage dips, short interruptions, and voltage changes for equipment with a current greater than 16A Electromagnetic compatibility testing and measurement techniques Voltage dips, short interruptions, and voltage changes for equipment with a main power supply current greater than 16A per phase Electromagnetic compatibility (EMC) GB/T 17626.34-2012 Part 4-34: Testing and measurement techniques Voltage dips for equipment with a main current greater than 16A per phase Short time interruption and voltage variation immunity test IEC 61000-4-34:2009 Voltage variation, voltage fluctuation and flicker (input current>16A and ≤ 75A per phase) Electromagnetic compatibility (EMC) - Part 3-11: Limits - Voltage variation in public low-voltage power supply systems Limitation of voltage fluctuations and flicker - Equipment with rated current ≤ 75A and conditional connection IEC 61000-3-11:2000 Harmonic current (input current>16A and ≤ 75A per phase) Electromagnetic compatibility (EMC) Part 3-12: Limits - Limits for harmonic currents generated by equipment connected to public low-voltage systems with input currents>16A and ≤ 75A per phase IEC 61000-3-12:2011 Pulse magnetic field immunity Electromagnetic compatibility testing and measurement techniques Pulse magnetic field immunity testing GB/T 17626.9-2011 IEC 61000-4-9:2001 Damping oscillation magnetic field immunity Electromagnetic compatibility testing and measurement techniques Damping oscillation magnetic field immunity testing GB/T 17626.10-1998 IEC 61000-4-10:1993 ————————————————Copyright Notice: This article is the original work of CSDN blogger "szhtw168" and follows the CC 4.0 BY-SA copyright agreement. Please attach the original source link and this statement when reprinting. Original link: https://blog.csdn.net/szhtw168/article/details/108019887

Function of testing report:

1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report

2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms

3. Used as a sales report: issuing legally effective testing reports to make consumers more confident

4. Papers and research: Provide professional personalized testing needs

5. Judicial services: providing scientific, fair, and accurate testing data

6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems

Baijian and testing process:

1. Telephone communication and confirmation of requirements

2. Recommend solutions and confirm quotations

3. Mail samples and arrange testing

4. Progress tracking and result feedback

5. Provide reports and after-sales service

6. If urgent or priority processing is required

Testing and testing characteristics:

1. The testing industry is fully covered, meeting different testing needs

2. Fully cover the laboratory and allocate localized testing nearby

3. Engineers provide one-on-one services to make testing more accurate

4. Free initial testing, with no testing fees charged

5. Self service order delivery for free on-site sampling

6. Short cycle, low cost, and attentive service

7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc

8. The testing report is authoritative and effective, and is generally used in China