
Scaffolds are various supports erected to ensure the operation and horizontal transportation of construction personnel. They are widely used in the construction industry and play a very important role in construction projects. Because different types of engineering construction require the use of scaffolding for different purposes, there are also many classifications of scaffolding p>
Product Standard Product Name Inspection Project DL/T 976-2005"Preventive Testing Regulations for Live Working Tools, Devices, and Equipment"
Insulation Support, Pull, and Hanger Appearance and Dimensions, Power Frequency Voltage Withstand Test, Operation Impact Voltage Withstand Test, Static Load Test, Dynamic Load Test, Insulation Bottle Holder Appearance and Dimensions, Power Frequency Voltage Withstand Test, Operation Impact Voltage Withstand Test, Static Bending Load Test Dynamic bending load test, insulation pulley appearance and size, power frequency withstand voltage test, tensile test, insulation operating rod appearance and size, power frequency withstand voltage test, operation impact withstand voltage test, bending and torsional static load test, bending dynamic load test, insulation hard ladder appearance and size, power frequency withstand voltage test, operation impact withstand voltage test, bending static load test, bending dynamic load test, insulation soft ladder appearance and size, power frequency withstand voltage test Operation impact withstand voltage test, tensile performance test, static load test of soft ladder head, dynamic load test of soft ladder head, appearance and size of insulation rope and cable tools, power frequency withstand voltage test, operation impact withstand voltage test, static tension test, appearance and size of insulation hand tools, power frequency withstand voltage test insulation (temporary) cross arm, insulation platform appearance and size, power frequency withstand voltage test insulation clothing (shawl) appearance and size Appearance and size of insulation sleeves for power frequency withstand voltage test of the entire clothing layer, inspection of markings, appearance and size of insulation gloves for AC or DC withstand voltage test, appearance and size of anti mechanical puncture gloves for AC withstand voltage test, DC withstand voltage test, appearance and size of insulation safety helmets for DC withstand voltage test, appearance and size of insulation shoes for AC withstand voltage test, appearance and size of insulation blankets for AC withstand voltage test Appearance and size of insulation pad for AC voltage withstand test, appearance and size of flexible shielding cover for AC voltage withstand test wire, appearance and size of shielding cover for AC voltage withstand test and DC voltage withstand test, appearance and size of grounding and short circuit device for AC voltage withstand test, power frequency voltage withstand test, operation impulse voltage withstand test, appearance and size of electrical appliance, power frequency voltage withstand test Leakage current test DL/T"Preventive Test Regulations for Electric Power Safety Tools"
Appearance inspection of safety helmets, impact performance test, puncture resistance performance test, safety belt appearance inspection, static load test safety rope appearance inspection, static load test buffer appearance inspection, static load test personal safety wire appearance inspection, group DC resistance test insulation rod appearance inspection, power frequency withstand voltage test DC withstand voltage test Appearance inspection of portable short-circuit grounding wire, group DC resistance test of grounding wire, power frequency withstand voltage test of grounding insulation rod (whole pole), DC withstand voltage test of grounding insulation rod (whole pole) Appearance inspection of capacitive electroscope, starting voltage test, power frequency withstand voltage test Appearance inspection of insulation cover, power frequency withstand voltage test, appearance inspection of insulation partition, surface power frequency withstand voltage test Appearance inspection of insulation rope for power frequency withstand voltage test, appearance inspection of insulation clamp for power frequency withstand voltage test, appearance inspection of auxiliary insulation gloves for power frequency withstand voltage test, appearance inspection of auxiliary insulation boots (shoes) for power frequency withstand voltage test, appearance inspection of auxiliary insulation rubber pads for power frequency withstand voltage test, appearance inspection of pole and foot buckles for power frequency withstand voltage test, overall static load test, and appearance inspection of climbing board (lifting board) for buckle strength test Appearance inspection of hard ladders (including bamboo ladders, wooden ladders, aluminum alloy ladders, composite material ladders, and step stools) for static load test, appearance inspection of soft ladders for static load test, appearance inspection of quick installation scaffolding for static load test, platform strength test, step strength test, maintenance platform (including high-altitude combination platform) appearance inspection, platform/suspension device strength Step strength GB 6095-2009"Safety belts"
General requirements for the overall structure of safety belts for pole work, general requirements for components, general requirements for webbing and ropes, overall static load of safety belts for pole work, overall sliding of safety belts for pole work, static load of components, dynamic load of components, mechanical properties of components, corrosion resistance, flame retardancy, suitability for special environments General requirements for the overall structure of safety belts with area restrictions, general requirements for components, general requirements for webbing and ropes, overall static load of safety belts with area restrictions, static load of components, dynamic load of components, mechanical performance of components, corrosion resistance, flame retardancy, adaptability to special environments, general requirements for the overall structure of fall arrest suspension safety belts, general requirements for components, general requirements for webbing and ropes Overall static load of fall arrest safety belts, overall dynamic load of fall arrest safety belts, static load of components, dynamic load of components, mechanical performance of components, corrosion resistance, flame retardancy, suitability for special environments, identificationFunction of testing report:
1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report
2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms 3. Used as a sales report: issuing legally effective testing reports to make consumers more confident 4. Papers and research: Provide professional personalized testing needs 5. Judicial services: providing scientific, fair, and accurate testing data 6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problemsBaijian and testing process:
1. Telephone communication and confirmation of requirements
2. Recommend solutions and confirm quotations 3. Mail samples and arrange testing 4. Progress tracking and result feedback 5. Provide reports and after-sales service 6. If urgent or priority processing is requiredTesting and testing characteristics:
1. The testing industry is fully covered, meeting different testing needs
2. Fully cover the laboratory and allocate localized testing nearby3. Engineers provide one-on-one services to make testing more accurate
4. Free initial testing, with no testing fees charged
5. Self service order delivery for free on-site sampling
6. Short cycle, low cost, and attentive service 7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc 8. The testing report is authoritative and effective, and is generally used in China