Electronics
Crystal transistor (bipolar transistor) detection
Crystal transistor (bipolar transistor) detection
Click here for online message:
Drop us a line
Service@Baijiantest.Com
Crystal transistor (bipolar transistor) detection

Distinguishing triode pins: usually based on the model, the arrangement of pins can be found in the manual. If the model is unknown, the resistance range of a multimeter can be used to distinguish the three poles e, b, and c

1. Distinguish the base and tube types and set the multimeter to R × 100 or R × In 1K gear, use a black lead to connect to one pin of the transistor, and a red lead to connect to the other two pins of the transistor until both measured resistance values are very low. The pin connected to the black lead is the base of the NPN transistor; If the above situation does not occur, the red lead should be connected to one pin of the transistor, and the black lead should be connected to the other two pins of the transistor until both measured resistance values are very small, and the pins connected to the red lead are all the base of the PNP transistor

2. Distinguish whether the collector and emitter will be connected to the meter set R × 1K gear, connect two probes to the other two pins of the tube at the same time, use a resistance of several tens of kiloohms or use a wet finger to connect between the base electrode and the assumed collector electrode, and observe the swing of the watch needle; Then use the same method to exchange the probes for measurement once. For NPN type tubes, if the probe swings more, the black probe is connected to the collector of the transistor, and the red probe is connected to the emitter of the transistor; For PNP type tubes, when the probe swings more, the red probe is connected to the collector of the transistor, and the black probe is connected to the emitter of the transistor

3. Distinguishing between germanium tube and silicon tube. By measuring the forward and reverse resistances of two PN junctions with a multimeter, it is possible to determine whether it is a germanium tube or a silicon tube. Generally, the forward resistance of a silicon tube is about 3-20 kiloohms, and the reverse resistance is greater than 500 kiloohms. The forward resistance of a germanium tube is about a few hundred ohms, and the reverse resistance is greater than 100 kiloohms.

4. Estimate the DC current amplification factor. Use the above method to distinguish the collector and emitter electrodes, and observe the swing of the watch needle. The larger the swing amplitude of the watch needle, the greater the current amplification factor 5. Estimating the Reverse Leakage Current of a Multimeter Setting R × At 1K gear, open the base electrode and measure the resistance between the collector and the emitter. For PNP tubes, connect the red and black probes to the collector and emitter respectively (NPN tubes are the opposite). The larger the measured resistance value, the smaller the reverse leakage current, and the more stable the performance of the transistor. Usually, silicon tubes are smaller than germanium tubes, high-frequency tubes are smaller than low-frequency tubes, and low-power tubes are smaller than high-power tubes. Note: There are significant differences in the method of using a digital multimeter to distinguish transistors, because for a digital multimeter, the black pen is connected to the negative electrode of the battery inside the meter, and the red pen is connected to the positive electrode. In addition, instead of using an ohmic scale for measurement, a PN junction scale is used for measurement

Function of testing report:

1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report

2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms

3. Used as a sales report: issuing legally effective testing reports to make consumers more confident

4. Papers and research: Provide professional personalized testing needs

5. Judicial services: providing scientific, fair, and accurate testing data

6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems

Baijian and testing process:

1. Telephone communication and confirmation of requirements

2. Recommend solutions and confirm quotations

3. Mail samples and arrange testing

4. Progress tracking and result feedback

5. Provide reports and after-sales service

6. If urgent or priority processing is required

Testing and testing characteristics:

1. The testing industry is fully covered, meeting different testing needs

2. Fully cover the laboratory and allocate localized testing nearby

3. Engineers provide one-on-one services to make testing more accurate

4. Free initial testing, with no testing fees charged

5. Self service order delivery for free on-site sampling

6. Short cycle, low cost, and attentive service

7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc

8. The testing report is authoritative and effective, and is generally used in China