Electronics
Detection of building electronic information lightning protection system
Detection of building electronic information lightning protection system
Click here for online message:
Drop us a line
Service@Baijiantest.Com
Detection of building electronic information lightning protection system

Due to its importance, building electronic information systems require comprehensive lightning protection measures, and their lightning protection devices are also an important part of lightning protection detection. Today, Lianya Testing shares the methods for determining lightning protection detection points in the system, as follows:

1. The electronic information room determines the detection points based on their lightning protection categories 2. Information storage, exchange, processing equipment, network communication hubs, safety protection equipment, signal surge protectors, indoor large metal objects, computer hosts, air conditioners, monitoring devices, various chassis (cabinets), operating consoles, control consoles, and their grounding resistance detection points should be determined based on their quantity 3. Ground resistance testing of various metal pipelines, heating pipes, distribution racks, metal wire trays, and line load-bearing metal supports entering and exiting the computer room shall be carried out according to the following methods to determine the testing points (1) For various types of metal pipelines and tracks of the same type, arranged in rows and groups, with reliable electrical connections between each other and a spacing of less than 100mm, the grounding resistance detection can be determined by group (row), but the two ends of each metal pipeline, track, etc. should be determined as the detection points When determining detection points based on the number of groups (rows) of facilities and equipment, not all detection points should be selected from the same facility or equipment within the group (row). Detection points should be dispersed or cross determined between each facility or equipment, and the detection points should be evenly distributed (3) For various types of metal pipes, ventilation pipes, trunking, pipeline wells, and other long metal objects, priority should be given to selecting their ends, branches, and turns as detection points. When conditions are limited, detection points can be selected at the nearest positions at both ends, branches, and turns 4. The grounding resistance detection of the busbar and grading ring in the computer room should be determined based on the number of grounding points 5. The grounding resistance testing of the low-voltage main distribution box (cabinet), dedicated distribution box, generator, storage box, UPS, working grounding, armored cable metal outer layer, etc. in the computer room should be determined based on the number of facilities and equipment. The performance testing of surge protective devices shall determine the detection points based on the number of detection parameters

Function of testing report:

1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report

2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms

3. Used as a sales report: issuing legally effective testing reports to make consumers more confident

4. Papers and research: Provide professional personalized testing needs

5. Judicial services: providing scientific, fair, and accurate testing data

6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems

Baijian and testing process:

1. Telephone communication and confirmation of requirements

2. Recommend solutions and confirm quotations

3. Mail samples and arrange testing

4. Progress tracking and result feedback

5. Provide reports and after-sales service

6. If urgent or priority processing is required

Testing and testing characteristics:

1. The testing industry is fully covered, meeting different testing needs

2. Fully cover the laboratory and allocate localized testing nearby

3. Engineers provide one-on-one services to make testing more accurate

4. Free initial testing, with no testing fees charged

5. Self service order delivery for free on-site sampling

6. Short cycle, low cost, and attentive service

7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc

8. The testing report is authoritative and effective, and is generally used in China