Electronics
Electromagnetic Compatibility Testing of Industrial, Scientific, and Medical (ISM) RF Equipment
Electromagnetic Compatibility Testing of Industrial, Scientific, and Medical (ISM) RF Equipment
Click here for online message:
Drop us a line
Service@Baijiantest.Com
Electromagnetic Compatibility Testing of Industrial, Scientific, and Medical (ISM) RF Equipment
Main Reference Standards

◆ CISPR 11/EN 55011/GB 4824: "Limits and Measurement Methods for Electromagnetic Disturbance Characteristics of Industrial, Scientific, and Medical (ISM) Radio Frequency Equipment" ◆ IEC 60601-1-2/YY 0505: "Medical Electrical Equipment Part 1-2: General Safety Requirements and Parallel Standards: Electromagnetic Compatibility Requirements and Tests"

◆ IEC 61326-1/GB T18268.1:

Electromagnetic compatibility requirements for electrical equipment used in measurement, control, and laboratory applications - Part 1: General requirements

◆ IEC 61326-2-6/GB T18268.26:

"Electromagnetic compatibility requirements for electrical equipment used in measurement, control, and laboratory applications - Part 26: Special requirements - In vitro diagnostic (IVD) equipment" ◆ IEC 61000-3-2/GB 17625.1: "Electromagnetic compatibility limits - Harmonic current emission limits (input current ≤ 16A per phase of equipment) ◆ IEC 61000-3-3/GB 17625.2: "Electromagnetic Compatibility Limits - Limitations on Voltage Changes, Voltage Fluctuations, and Flashing of Equipment with Rated Current ≤ 16A per Phase and Unconditional Access in Public Low Voltage Power Supply Systems"

EMI Test Items

◆ Conducted Disturbance Voltage, 150kHz to 30MHz, QP/AV ◆ Click Sound, 150kHz to 30MHz, QP ◆ Magnetic Induction Current, 9kHz to 30MHz, QP ◆ Radiated Disturbance (Magnetic Field), 9kHz to 30MHz, QP ◆ Radiation disturbance (electric field), 150kHz -1GHz, QP; 1GHz to 18GHz, PEAK/weighted ◆ harmonic current emission test, tested according to IEC 61000-3-2 ◆ voltage fluctuation and flicker test, tested according to IEC 61000-3-3

EMS Test Items

◆ electrostatic discharge immunity, contact discharge 6kV, air discharge 8kV ◆ RF electric field radiation immunity, maximum test field strength 10V/m ◆ electrical fast transient group pulse immunity, maximum test level 2kV ◆ surge (impact) immunity, Maximum test level 2kV ◆ Immunity to RF conducted disturbances, maximum test level 10V ◆ Immunity to power frequency magnetic fields, maximum test field strength 3A/m ◆ Immunity to voltage dips, short interruptions, and voltage changes, according to IEC61000-4-11

Function of testing report:

1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report

2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms

3. Used as a sales report: issuing legally effective testing reports to make consumers more confident

4. Papers and research: Provide professional personalized testing needs

5. Judicial services: providing scientific, fair, and accurate testing data

6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems

Baijian and testing process:

1. Telephone communication and confirmation of requirements

2. Recommend solutions and confirm quotations

3. Mail samples and arrange testing

4. Progress tracking and result feedback

5. Provide reports and after-sales service

6. If urgent or priority processing is required

Testing and testing characteristics:

1. The testing industry is fully covered, meeting different testing needs

2. Fully cover the laboratory and allocate localized testing nearby

3. Engineers provide one-on-one services to make testing more accurate

4. Free initial testing, with no testing fees charged

5. Self service order delivery for free on-site sampling

6. Short cycle, low cost, and attentive service

7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc

8. The testing report is authoritative and effective, and is generally used in China