1、 Product features 1. Adopting imported high-precision PID sensors from the United States 2. 8-inch wide touch screen display 3. Modular design for easy equipment maintenance 4. Primary pre-treatment system composed of built-in flow meters, dust filters, etc. 5. Adopting explosion-proof box integration, explosion-proof grade EX De IICT4, IP65 6. With data storage function, it can store historical data for more than 3 years 7 It has functions such as automatic testing, self inspection, fault alarm, screen display, and result query. 8. It is equipped with meteorological monitoring sensors, which are designed using a solid and durable ultrasonic principle, and the entire system is maintenance free. 9. Modbus communication can be connected to the upper computer, and is compatible with conventional control output methods: 1 relay output. 10. The full Chinese operation interface (which can be converted into English interface). 11. The rainproof and dustproof shell design is 12 Pump suction sampling 13. Can add 4 to 8 gas monitoring factors, and select according to on-site pollution factors. 2. Equipment introduction SKA/NE-VOC-EX is an explosion-proof VOC online monitoring instrument produced by Shenzhen Shengkaian Technology Co., Ltd., mainly used for monitoring the concentration of gas emitted from unorganized emissions in factories, workshops, and industrial parks. Considering the particularity of the factory boundary environment, the detection of five meteorological parameters such as wind direction, wind speed, temperature, humidity, and air pressure has been added. It can be equipped with DTU or environmental data acquisition instruments, and can be connected to environmental protection platforms and cloud platforms. Realize remote network monitoring by connecting the cloud data of the monitoring instrument, and the transmission is not limited by distance. Establish a boundary data monitoring and analysis system to further improve the processing and management capabilities of boundary air pollution monitoring data, and provide decision-making basis for environmental planning and evaluation p> 3. Technical indicators Sensor type PID Photoion gas type TVOC sampling method Pump suction gas range 0-20ppm, 200ppm, 1000ppm, 2000ppm, 10000ppm Resolution 0.001, 0.01, 0.1, 1ppm Accuracy ≤ ± 2% FS Repeatability ≤ ± 2% F S Zero drift ≤ ± 2% F S/6 h Span drift ≤ ± 5% F S/6 h Response time T90< 3S ultrasonic meteorological five parameter sensor detection indicators (optional) Temperature measurement range -50~85 ° C (configurable) Accuracy ± 0.2 (configurable) Humidity measurement range 0~100% Relative humidity, accuracy ± 2% Relative humidity (configurable) Air pressure measurement range 300~1200 kPa (configurable) Accuracy ± 0.3 kPa (configurable) Wind direction principle Ultrasonic, measurement range 0~360 ° Accuracy ± 3 ° (configurable) Wind speed principle Ultrasonic, measurement range 0-60 meters/second Accuracy: measurement value plus or minus 0.3 meters/second or 3%
4. Equipment parameters: power supply 220VAC or 24VDC, Optional battery and solar cell pack (working for more than 8 hours after power outage) sampling method: pump suction pre-treatment system dust filter+primary filter two-stage filtering output signal RS485 (modbus RTU) digital signal - default (connected to DTU, data acquisition instrument or personal computer); 4-20MA connected to PLC/DCS system (optional) GPRS wireless transmission, supporting (HJ/T 212) communication protocol docking with Environmental Protection Bureau (optional) display screen 8-inch configuration industrial serial port screen box size 470 * 570 * 225 (MM) built-in high-precision gas intelligent detection module
Function of testing report:
1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report
2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms 3. Used as a sales report: issuing legally effective testing reports to make consumers more confident 4. Papers and research: Provide professional personalized testing needs 5. Judicial services: providing scientific, fair, and accurate testing data 6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problemsBaijian and testing process:
1. Telephone communication and confirmation of requirements
2. Recommend solutions and confirm quotations 3. Mail samples and arrange testing 4. Progress tracking and result feedback 5. Provide reports and after-sales service 6. If urgent or priority processing is requiredTesting and testing characteristics:
1. The testing industry is fully covered, meeting different testing needs
2. Fully cover the laboratory and allocate localized testing nearby3. Engineers provide one-on-one services to make testing more accurate
4. Free initial testing, with no testing fees charged
5. Self service order delivery for free on-site sampling
6. Short cycle, low cost, and attentive service 7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc 8. The testing report is authoritative and effective, and is generally used in China