Testing standards for high-voltage isolation switches: GB1985

GB 1985 2014 high-voltage AC isolation switches and grounding switches

This standard is applicable to AC isolation switches and grounding switches designed and installed indoors and outdoors, and operating in systems with a frequency of 50Hz and a nominal voltage of 3000V or above, with closed and open terminals

This standard also applies to the operating mechanisms and auxiliary equipment of these isolation switches and grounding switches.

Note: This standard does not include isolation switches that use fuses as a component

The main differences between GB1985-2014 and GB1985-2004 are:

- According to IEC62271-102:2001+A1:2011, the definitions of the terms "combined function grounding switch" and "unlocking point" have been added; Add definitions for the terms "M1 level grounding switch" and "M2 level grounding switch" as needed

-  Add relevant technical requirements for rated voltage 1100kV isolation switches and grounding switches

-  Change the rated short-circuit duration of the grounding switch from 2 seconds to at least 2 seconds

-  Added the recommended rated terminal static mechanical load for isolation switches with rated voltages of 24kV and 31.5kV

-  Revised the mechanical life ratings of M1 level isolation switches and grounding switches

-  Added the rated bus transfer voltage of the 40.5kV isolation switch

-  Revised the specified value of the charging current opening and closing capacity of the isolation switch busbar in gas insulated metal enclosed switchgear; Added the rated value of the small capacitive current switching capacity of the air insulated isolation switch

-  Added the rated value of the small inductive current opening and closing capacity of the isolation switch

-  Revised the standard values of rated induced current and rated induced voltage for Class B grounding switches, as well as relevant test circuit parameters

Function of testing report:

1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report

2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms

3. Used as a sales report: issuing legally effective testing reports to make consumers more confident

4. Papers and research: Provide professional personalized testing needs

5. Judicial services: providing scientific, fair, and accurate testing data

6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems

Baijian and testing process:

1. Telephone communication and confirmation of requirements

2. Recommend solutions and confirm quotations

3. Mail samples and arrange testing

4. Progress tracking and result feedback

5. Provide reports and after-sales service

6. If urgent or priority processing is required

Testing and testing characteristics:

1. The testing industry is fully covered, meeting different testing needs

2. Fully cover the laboratory and allocate localized testing nearby

3. Engineers provide one-on-one services to make testing more accurate

4. Free initial testing, with no testing fees charged

5. Self service order delivery for free on-site sampling

6. Short cycle, low cost, and attentive service

7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc

8. The testing report is authoritative and effective, and is generally used in China