A transformer is a component with primary and secondary windings as its core. When using a multimeter for testing, it can be determined whether the transformer is damaged by detecting the winding resistance value Detection of Transformer Winding Resistance: The detection of transformer winding resistance mainly includes three aspects: detection of the resistance of the primary and secondary windings themselves, detection of insulation resistance between windings, and detection of insulation resistance between windings and iron cores or shells. Before detecting the resistance of the transformer winding, the winding pins of the transformer to be tested should be distinguished first

1 Adjust the range knob of the multimeter to the Ohm position, and place the red and black probes on the two pins of the primary winding or the two pins of the secondary winding of the transformer to be tested. Observe the display screen of the multimeter, and under normal circumstances, there should be a fixed value. If the measured resistance value is infinite, it indicates that there is an open circuit phenomenon in the measured winding

2 Adjust the range knob of the multimeter to the Ohm position, and place the red and black probes on any two pins of the primary and secondary windings of the transformer to be tested. Observe the display screen of the multimeter, which should be infinite under normal circumstances. If there is a certain resistance value or a small resistance value between the windings, it indicates that there is a short circuit phenomenon between the measured transformer windings

3 Adjust the range knob of the multimeter to the Ohm position, and place the red and black probes on the primary winding pins and iron core of the transformer to be tested. Observe the display screen of the multimeter, which should be infinite under normal circumstances. If there is a certain resistance value or a small resistance value between the winding and the iron core, it indicates that there is a short circuit between the measured transformer winding and the iron core

Function of testing report:

1. Project bidding: Issue authoritative third-party CMA/CNAS qualification report

2. Online e-commerce platform entry: Quality inspection report recognized by major e-commerce platforms

3. Used as a sales report: issuing legally effective testing reports to make consumers more confident

4. Papers and research: Provide professional personalized testing needs

5. Judicial services: providing scientific, fair, and accurate testing data

6. Industrial problem diagnosis: Verify the troubleshooting and correction of industrial production problems

Baijian and testing process:

1. Telephone communication and confirmation of requirements

2. Recommend solutions and confirm quotations

3. Mail samples and arrange testing

4. Progress tracking and result feedback

5. Provide reports and after-sales service

6. If urgent or priority processing is required

Testing and testing characteristics:

1. The testing industry is fully covered, meeting different testing needs

2. Fully cover the laboratory and allocate localized testing nearby

3. Engineers provide one-on-one services to make testing more accurate

4. Free initial testing, with no testing fees charged

5. Self service order delivery for free on-site sampling

6. Short cycle, low cost, and attentive service

7. Possess authoritative qualifications such as CMA, CNAS, CAL, etc

8. The testing report is authoritative and effective, and is generally used in China